Distributori
autorizzati
 |
Altri marchi trattati |

 |

PARKER-LUCIFER |
|
|
|
|
Home > Sensori a ultrasuoni > Sensori unità controllo separata
| 1. |
UB2000-30GM-H3
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -30GM, Diameter of the housing: 30 mm, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: 2 m, PVC cable 0.75 mm²
|
| 2. |
UB2000-30GM-H3-V1
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -30GM, Diameter of the housing: 30 mm, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: V1 connector (M12 x 1), 4-pin
|
| 3. |
UB2000-30GM-H3-Y221102
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, With clock pulse output, Series: -30GM, Diameter of the housing: 30 mm, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: 2 m PVC cable 0.34 mm², Operating voltage: 10 ... 30 V DC , ripple 10 % SS, Sensing range: 80 ... 2000 mm, Sensing range: 80 ... 2000 mm
|
| 4. |
UB2000-F54-H3-V1
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -F54, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: V1 connector (M12 x 1), 4-pin, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V)
|
| 5. |
UB4000-30GM-H3-V1
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -30GM, Diameter of the housing: 40 mm, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: V1 connector (M12 x 1), 4-pin
|
| 6. |
UB500-30GM-H3-V1
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -30GM, Diameter of the housing: 30 mm, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: V1 connector (M12 x 1), 4-pin
|
| 7. |
UB500-F54-H3-V1
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -F54, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: V1 connector (M12 x 1), 4-pin, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V)
|
| 8. |
UB6000-30GM-H3-V1
|
|
|
Ultrasonic sensor - Single head system, Separate evaluation, Direct detection mode, Series: -30GM, Diameter of the housing: 74 mm, Output type: 1 pulse output for echo run time, short-circuit proof open collector pnp with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): >= (+U B-2 V), Connection: V1 connector (M12 x 1), 4-pin
|
| 9. |
UBE15M-F54-H1-V1
|
|
|
Ultrasonic sensor - Multi-head system, Large sensing range, Large possible lateral distance between emitter and receiver, Separate evaluation, Series: -F54, Connection: V1 connector (M12 x 1), 4-pin, Operating voltage: 16 ... 30 V DC , ripple 10 % SS 8 V DC at less transmitting power, Sensing range: 0 ... 15000 mm , emitter - receiver synchronised, Sensing range: 0 ... 15000 mm , emitter - receiver synchronised, Operating voltage: 16 ... 30 V DC , ripple 10 % SS 8 V DC at less transmitting power
|
| 10. |
UBE15M-F54-H2-V1
|
|
|
Ultrasonic sensor, receiver - Multi-head system, Large sensing range, Large possible lateral distance between emitter and receiver, Separate evaluation, Series: -F54, Output type: 1 pulse output for echo propagation time, open collector npn, short-circuit proof 0 level (active): U OL <= 2 V, I OL <= 15 mA 1 level (inactive): U OH = U B (pull-up R = 330 kOhm), Connection: V1 connector (M12 x 1), 4-pin, Operating voltage: 10 ... 30 V DC , ripple 10 % SS, Sensing range: 0 ... 15000 mm , emitter - receiver synchronised
|
|
|