Home > Sensori optoelettronici > Barriere ottiche


Prodotti
In ordine di :
31. PLVScanP40-1892-48/47/139
Profile light grid - Light grid for profile monitoring, Beam spacing 48.5 mm, Separate outputs for height monitoring, Programmable via Windows software, Adjustable beam crossover, Effective detection range: 3 ... 8 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) , 4 pnp, short-circuit proof, light ON (height monitoring), Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 40, Beam spacing: 48.5 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

32. PLVScanP48-0940-20/47/139
Profile light grid - Light grid for profile monitoring, Beam spacing 20 mm, Separate outputs for height monitoring, Programmable via Windows software, Adjustable beam crossover, Effective detection range: 1.5 ... 4 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) , 4 pnp, short-circuit proof, light ON (height monitoring), Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 20 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

33. PLVScanP48-0940-20/47/86
Profile light grid - Measuring light grid, Beam spacing 20 mm, RS 232 interface for data transmission and configuration, Programmable via Windows software, Sturdy design, Effective detection range: 1.5 ... 4 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) and 1 x RS 232 interface with serial data output, Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 20 mm, Field height: 940 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

34. PLVScanP48-2000-42-2605/32/139
Profile light grid - Light grid for profile monitoring, Detection range up to 6 m, Separate outputs for height monitoring, Beam spacing 42.5 mm, Programmable via Windows software, Effective detection range: 1.5 ... 4 m, Signal output: 1 pnp, short-circuit proof (monitoring field) , 3 pnp, short-circuit proof, light ON(height monitoring), Connection: Emitter: M16 connector, 5-pin , Receiver: M16 connector, 8-pin, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 42.5 mm, Field height: 2000 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

35. PLVScanP48-2000-42/47/139
Profile light grid - Light grid for profile monitoring, Beam spacing 42.5 mm, Separate outputs for height monitoring, Programmable via Windows software, Adjustable beam crossover, Effective detection range: 1.5 ... 4 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) , 4 pnp, short-circuit proof, light ON (height monitoring), Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 42.5 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

36. PLVScanP48-2000-42/47/86
Profile light grid - Measuring light grid, Beam spacing 42.5 mm, RS 232 interface for data transmission and configuration, Programmable via Windows software, Sturdy design, Effective detection range: 1.5 ... 4 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) and 1 x RS 232 interface with serial data output, Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 42.5 mm, Field height: 2000 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

37. PLVScanP48-2280-48-2791/32
Profile light grid - Light grid for profile monitoring, Beam spacing 48 mm, 5-fold chipping, Sturdy design, Cable with M12 plug, Effective detection range: 3 ... 8 m , preset to 2 m, Signal output: 1 pnp, short-circuit proof (monitoring field), Connection: Connecting cable 250 mm with M12 connector, 5 pin, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 48 mm, Field height: 2280 mm, RS 232 interface, Calibration input

Categoria:   Sensori optoelettronici > Barriere ottiche

38. PLVScanP48-2280-48/47/139
Profile light grid - Light grid for profile monitoring, Beam spacing 48.5 mm, Separate outputs for height monitoring, Programmable via Windows software, Adjustable beam crossover, Effective detection range: 3 ... 8 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) , 4 pnp, short-circuit proof, light ON (height monitoring), Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 48, Beam spacing: 48.5 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

39. PLVScanP56-2340-42-2606/32/139
Profile light grid - Light grid for profile monitoring, Detection range up to 6 m, Separate outputs for height monitoring, Beam spacing 42.5 mm, Programmable via Windows software, Effective detection range: 1.5 ... 4 m, Signal output: 1 pnp, short-circuit proof (monitoring field) , 3 pnp, short-circuit proof, light ON(height monitoring), Connection: Emitter: M16 connector, 5-pin , Receiver: M16 connector, 8-pin, Test input, Sensitivity adjustment, Number of beams: 56, Beam spacing: 42.5 mm, Field height: 2340 mm

Categoria:   Sensori optoelettronici > Barriere ottiche

40. PLVScanP56-2340-42/47/139
Profile light grid - Light grid for profile monitoring, Beam spacing 42.5 mm, Separate outputs for height monitoring, Programmable via Windows software, Adjustable beam crossover, Effective detection range: 1.5 ... 4 m , can be reduced to > 0.3 m, Signal output: 2 pnp, antivalent. short-circuit proof (monitoring field) , 4 pnp, short-circuit proof, light ON (height monitoring), Connection: terminal compartment PG9 with screw terminals, Test input, Sensitivity adjustment, Number of beams: 56, Beam spacing: 42.5 mm

Categoria:   Sensori optoelettronici > Barriere ottiche